- ページ 17

サーバー Dell PowerEdge R610のPDF メンテナンスとトラブルシューティングをオンラインで閲覧またはダウンロードできます。Dell PowerEdge R610 24 ページ。 Poweredge series
Dell PowerEdge R610 にも: ドキュメンテーション・アップデート (14 ページ), 更新マニュアル (32 ページ), 情報更新 (14 ページ), 情報更新 (38 ページ), 更新マニュアル (44 ページ), インストレーション・インストラクション (2 ページ), マニュアル (10 ページ), ハードウェア取り付け説明書 (2 ページ), 更新マニュアル (14 ページ), ポートフォリオ・マニュアル (27 ページ), データシート (2 ページ)

Dell PowerEdge R610 メンテナンスとトラブルシューティング
Code
Text
E1116
Temp Memory
E12nn
xx PwrGd
E1210
CMOS Batt
E1211
ROMB Batt
E1216
3.3V Regulator
failure
E1229
CPU # VCORE
E122A
CPU # VTT
Regulator failure
E122C
CPU Power Fault
E122D
Memory Regulator #
Failed
E122E
On-board regulator
failed.
E1310
RPM Fan ##
E1311
RPM Fan Mod #x
E1313
Fan Redundancy
November 2010
Causes
Memory has exceeded
acceptable temperature and
has been disabled to prevent
damage to the components.
Specified voltage regulator
has failed.
CMOS battery is missing, or
the voltage is out of
acceptable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
3.3V voltage regulator has
failed.
Processor # VCORE voltage
regulator has failed.
Specified processor VTT
voltage regulator has failed
A power fault was detected
when powering up the
processor(s).
One of the memory
regulators has failed.
One of the on-board voltage
regulators failed.
RPM of specified cooling fan
is out of acceptable operating
range.
RPM of fan x in the # module
is out of acceptable operating
range.
The system is no longer fan-
redundant. Another fan
Maintaining and Troubleshooting the Dell
Comments on this document? [email protected]
LCD status message explanations
Corrective action
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
Escalate for possible server
replacement.
Shut down server for 1 hour and
disconnect the power supply. If
problem continues, escalate for
possible server replacement.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
See HOM: Troubleshooting
Expansion Cards. Turn off the system
and attached peripherals. Power
down system and unplug power cord.
Open system and ensure that
expansion card riser and expansion
card are firmly seated. Close system,
power up. If trouble persists, replace
card.
Escalate for possible server
replacement.
Replace the server.
Remove AC power to the system for
10 seconds and restart the system.
Reseat the memory modules.
Remove AC power to the system for
10 seconds and restart the system.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
Check room temperature and external
air flow. If both are within acceptable
Table continues...
PowerEdge
R610 Server
17