- ページ 7
防犯カメラ Avue High Speed dome Camera SeriesのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Avue High Speed dome Camera Series 15 ページ。 High speed dome camera series
4.INSTALLATION
Installing the core unit to base board.
The PTZ camera core unit and base board are packed seperatly, in order to be
protected through the transportation. After unpaking and during the installation, the
core unit should be installed as following:
Installing the core unit by
pushing into the
housing.please note the
position of connector. For
releasing, please press the
lever-lock to core and pull off
the unit.
Once the base board is connected to power,
the power LED will light.
Connector
Interface
Power
LED
Metal
Clip
WARNING:
Do not pull or hold the connector interface with force. It
is design only to connect the core unit and the base
board. Any presure on connector will cause damage and
avoids the warranty.
Optional bracket accessories
The PTZ cameras can be equipped with various bracket accessories for indoor
and outdoor installation. please contact your distributor for further details.
Ceilling
Wall mount and
Corner
mount
Power box
Mount
Indoor
Indoor ceilling
embedded
mount
9
mount
Some products may not be available in your country, please contact our distributor for more details
Lever-
Lock
Heater connector
on outdoor
Rubber ring
housing
Safety spring
cable
Heater connector
Outdoor
housing cover
Screws
Indoor Wall
Pole
Outdoor
mount
Mount
Power Box
Extended wall
Wall
Swan-Neck
mount
Mounting
mount
bracket
5.OPERATING THE SPEED DOME
Initial Screen
After powering up, the camera will enter the
FIRMWARE V2.61
self-test mode and display the status screen(
Protocol: PELCO
as in the picture left).It contains information
Dome Address: 001
Comm 9600,N,8,1
about the model and current settings.
- V2.61:
Current firmware version
- Protocol:
control protocol which currently used
- Dome address:
Address ID of speed dome. please refer to the section "Protocol
setup " for details.
- Comm 9600,N,8,1:
current setting of the serial communication interface.
9600:
Baud rate. please refer to section "Baud-Rate setup" for details
N, 8, 1:
No parity bit, 8 bit length, 1 stop bit. this setting can not be changed
The intial screen will stay remain on until any user action is being taken. If the power-
up action is set, the initial info wil vanish immediatly.
Operation Screen
The operation screen can display additional
information.
Temperature: current temperature inside the
speed dome( °C)
Cam title:
User definable camera title
Zone:
Current zone name
Pan deg.:
Pan angle, 0-359°
Tilt deg.:
Tilt angle, 0-90°
Zoom Factor: Zoom factor
Display of the information can be activate or
deactivate through the OSD menu. please refer to
the system setting for detais.
PTZ operation
For the surveillance operation, the dome can be controlled from a keyboard device,
Multiplexer or DVR through RS-485 Interface. Make sure that the cable is connected
and the settings (baud rate, Address ID and protocol) of both keyboard and the dome
are configured correctly. For more description about the PTZ operation, please refer
to the user's manual of the keyboard.
Some products may not be available in your country, please contact our distributor for more details
Temperature
CAM TITLE
32.0
ZONE-1
285 78
18X
Zoom factor
Tilt degree
Pan degree
Zone description
10