- ページ 18

アクセサリー ensto PXA53のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。ensto PXA53 20 ページ。

PARAMETERS:
SENS-potentiometer: Setting minimum light level (dimming level)
5 %
20 %
LUX-potentiometer: Setting maximum light level
80 %
100 %
TIME-potentiometer: Setting after-glow time
1 hour
Always ON
5.2 Changing adjustments:
-
+
1-10V
L, N: 220-240VAC µ 50/60Hz
A, B: 220-240VAC
2A
LUX: 1lx -
TIME: 1-30 min
LUX
SENS
PXA 53
TEST
-
+
1-10V
L, N: 220-240VAC µ 50/60Hz
A, B: 220-240VAC
2A
LUX: 1lx -
TIME: 1-30 min
SENS
LUX
PXA 53
TEST
18
potentiometer to MIN (factory setup)
potentiometer to MAX
potentiometer to MIN
potentiometer to MAX (factory setup)
potentiometer to MIN
potentiometer to MAX (factory setup)
SENS The SENS potentiometer permits adjustment of the sensitivity of the
sensor to movement. Note that also the sensor's detection area may be
altered.
TEST Turning the SENS potentiometer moves the sensor in the test mode.
This test mode lasts for 3 minutes from the last adjustment of the SENS
potentiometer. In the test mode the green and red LEDs flash alternately.
In the test mode the detection area can be tested by walking across in
front of the sensor, causing the light fitting to switch on in response to the
movement for approx. 5 seconds. The sensitivity during a test will be at the
level indicated on the SENS potentiometer. After switch off there is a delay
of approx. 2 seconds before switching on again.
TIME The TIME potentiometer enables the length of time the light remains
on after the sensor's last reaction to movement to be adjusted. The horizontal
arrow points to 1 minutes. The setting range is 1 min - 30 min.