- ページ 6

水システム EarthLinked HCM-4272CのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。EarthLinked HCM-4272C 11 ページ。 Hybrid cooling module

5. On a solid, level mounting pad. The mounting pad should extend a minimum of 2 inches
beyond the cabinet size of the Hybrid Cooling Module. The minimum pad size is to be 22
inches by 46 inches. The pad should NOT be in contact with or be an integral part of the
building foundation. The following DiversiTech Pads (or their equivalent) are recommended.
The standard pads are 2inches thick. Local building codes may require a 3 inch thick pad.
Model Number
Ultralite
Ultralite
Elite
Elite
6. Where conditions or local codes require the Hybrid Cooling Module to be attached to a
mounting pad or frame, tie down bolts should be used to fasten through the holes provided
in the Hybrid Cooling Module feet.
7. Elevate the Hybrid Cooling Module per local climate and code requirements to provide
clearance above estimated snowfall level and ensure adequate water drainage of Hybrid
Cooling Module. Use snow stand in areas where prolonged freezing temperatures are
encountered.
Do NOT Locate the Hybrid Cooling Module:
1.
On brick, concrete blocks or unstable surfaces
2.
Near clothes dryer exhaust vents
3.
Near sleeping area or near windows
4.
Under eaves where water, snow or ice can fall directly in the unit
5.
Within clearance less than 2 Feet from a second unit
6. Within the minimum distance the Hybrid Cooling Module can be installed from the property
line, where local zoning ordinances apply.
HCM-410CP-IM (12/15)
®
UC2448-2
®
UC2448-3
®
EL3648-2
®
EL3648-3
Size, Inches
Comments
24 x 48 x 2
Fiber-cement construction
24 x 48 x 3
Fiber-cement construction
Plastic-drillable for securing
36 x 48 x 2
Plastic-drillable for securing
36 x 48 x 3
unit
unit
Page 6