Figure 18. Installing a drive blank
Removing the drive carrier
Remove the drive carrier from the enclosure to replace the drive.
Prerequisites
Use the system manager software to prepare the drive for removal. If the drive is online, the green activity or fault indicator
blinks while the drive is powering off. When the drive indicators are off, the drive is ready for removal.
Steps
1. If installed,
remove the front
2. Press the release button to open the drive carrier release handle.
3. Holding the drive carrier release handle, slide the drive carrier out of the drive slot.
Figure 19. Removing a drive carrier
Removing the drive from the drive carrier
Prerequisites
Follow the safety guidelines listed in the
Steps
1. Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier.
NOTE:
If the carrier has a Torx screw, use a Torx 6 (for 2.5-inch drive) or Torx 8 (for 3.5-inch drive) screwdriver to
remove the drive.
2. Lift the drive out of the drive carrier.
bezel.
Safety
precautions.
Replacing components
23