- ページ 10

スイッチ Dell N1108P-ONのPDF スタートマニュアルをオンラインで閲覧またはダウンロードできます。Dell N1108P-ON 27 ページ。

Dell N1108P-ON スタートマニュアル
2 Insert the supplied bolts into the rack-mounting holes and tighten with a
screwdriver.
3 Repeat the process for the rack-mounting bracket on the other side of the
switch.
4 Insert the switch into the 48.26 cm (19 inch) rack, ensuring that the rack-
mounting holes on the bracket line up with the mounting holes in the
rack.
5 Secure the bracket to the rack with either the rack bolts or cage nuts and
cage-nut bolts with washers (depending on the kind of rack you have).
Fasten the bolts on the bottom before fastening the bolts on the top.
CAUTION:
rack.
NOTE:
Make sure that the ventilation holes are not obstructed.

Wall Installation for N1108T-ON and N1108P-ON

To mount the switch on a wall:
1 Make sure that the mounting location meets the following requirements:
The surface of the wall must be capable of supporting the switch.
Allow at least two inches (5.1 cm) space on the sides for proper
ventilation and five inches (12.7 cm) at the back for power cable
clearance.
The location must be ventilated to prevent heat buildup.
2 Place the supplied wall-mounting bracket on one side of the switch,
verifying that the mounting holes on the switch line up to the mounting
holes on the wall-mounting bracket.
10
Getting Started Guide
Make sure that the supplied rack bolts fit the pre-threaded holes in the