- ページ 37
スイッチ Dell Networking S4048のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Dell Networking S4048 44 ページ。
Dell Networking S4048 にも: スタートマニュアル (24 ページ)
This chapter lists the S4048–ON specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 113°F (45°C).
CAUTION:
Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same
or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
Topics:
•
Chassis physical design
•
IEEE standards
•
Agency compliance
Chassis physical design
Table 5. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Table 6. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Specifications
Specifications
1.71 inches (43.5 mm)
17.09 inches (434 mm)
18.11 inches (460 mm)
21.7 lbs (9.86 kg)
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Specifications
32° to 113°F (0° to 45°C)
5 to 85% (RH), non-condensing
–40° to 158°F (–40° to 70°C)
5 to 95%, non-condensing
1153.265 BTU/hr
10,000 feet (3,048 meters)
No performance degradation to 35,000 feet (10,668 meters)
Meets Bellcore Zone 4 earthquake requirements (MIL-STD-810)
9
Specifications
37