スイッチ Dell PowerConnect B-7500のPDF 交換手順をオンラインで閲覧またはダウンロードできます。Dell PowerConnect B-7500 6 ページ。 Fan assembly

Dell PowerConnect B-7500 交換手順

In this guide

Fan assembly replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Time required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Items required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Replacing a switch fan assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Fan assembly replacement
This group of switches has three fan assemblies as displayed in
1
Fan Assembly 1
3
Fan Assembly 3
FIGURE 1
Fan assemblies on the nonport side
CAUTION
Disassembling any part of the fan assembly voids the part warranty and regulatory certifications. There
are no user-serviceable parts inside the fan assembly.
Because the cooling system relies on pressurized air, do not leave any of the fan assembly slots empty
longer than two minutes while the switch is operating. If a fan assembly fails, leave it in the switch until it
can be replaced.
Maintain all three fan assemblies in operational condition to provide redundancy.
Table 1
describes the fan status LED colors, behaviors, and actions required, if any.
TABLE 1
Fan status LED behavior, description, and required actions
LED color and behavior
No light.
Steady green.
Steady amber (for more
than five seconds).
Fan Assembly Replacement Procedure
53-1001790-01
3
2
Fan Assembly 2
Description
Fan assembly is not receiving power.
Fan assembly is operating normally.
Fan fault for one of the following reasons:
one or more of the fan(s) in the fan assembly
has failed
the fan FRU was disabled by the user
Figure
1.
2
1
Action required
Verify that the fan FRU is seated correctly.
No action required.
Verify that the fan FRU is enabled. If the fan FRU is
enabled and the FRU is faulty it should be
replaced.
3