- ページ 15

スイッチ Dell PowerEdge M IO AggregatorのPDF スタートマニュアルをオンラインで閲覧またはダウンロードできます。Dell PowerEdge M IO Aggregator 38 ページ。 Dell poweredge m i/o aggregator getting started guide

Table 1-3 describes the LED status of a 40GbE QSFP+ port that is split into
four 10GbE SFP+ ports using a 4x10GbE breakout cable.
Ta b l e 1 - 3 .
L E D S t a t u s o f 4 x 1 0 G b E P o r t
Port LED
Color
Off
Link Status
Yellow
Off
Activity
Blinking
Green

Installation

Site Preparation

Before installing the switch or switches, ensure that the chosen installation
location meets the following site requirements:
Clearance — There is adequate front and rear clearance for operator
access. Allow clearance for cabling, power connections, and ventilation.
Cabling — The cabling is routed to avoid sources of electrical noise such
as radio transmitters, broadcast amplifiers, power lines, and fluorescent
lighting fixtures.
Ambient Temperature — The ambient switch operating temperature
range is 10° to 40ºC (50° to 104ºF).
NOTE:
Decrease the maximum temperature by 1°C (1.8°F) per 300 m (985 ft.)
above 900 m (2955 ft.).
Relative Humidity — The operating relative humidity is 8% to 85% (non-
condensing) with a maximum humidity gradation of 10% per hour.
Meaning
All four 10GbE ports on a breakout cable are down.
At least one of the four 10GbE ports on a breakout
cable is up.
No traffic is being transmitted on any 10GbE port on
the breakout cable.
Traffic is being transmitted or received on at least one
of the 10GbE ports on the breakout cable.
Hardware Overview
15