The S25N, S25V, and S25P systems do not have a dedicated management port,
nor a separate management routing able. Configure any port on one of the
chassis to be the port through which you manage the system and configure an IP
route to that gateway.
Step Task
Configure an IP address for the
1
port through which you will
manage the system.
Configure an IP route with a
2
default gateway.
Configure a username and
3
password.
Configure the Management Port IP Address
Assign IP addresses to the management ports in order to access the system
remotely.
NOTE: Assign different IP addresses to each RPM's management port.
Step Task
Enter INTERFACE
1
mode for the
Management port.
Assign an IP address
2
to the interface.
Enable the interface.
3
Configure a Management Route
Define a path from the system to the network from which you are accessing the
system remotely. Management routes are separate from IP routes and are only
used to manage the system through the management port.
Command Syntax
ip address
ip route
username
Command Syntax
interface ManagementEthernet
slot/port
ip address ip-address/mask
no shutdown
Command Mode
INTERFACE
CONFIGURATION
CONFIGURATION
Command Mode
CONFIGURATION
INTERFACE
INTERFACE
Installing the Software