- ページ 13

スイッチ Dell S4048-ONのPDF トラブルシューティングマニュアルをオンラインで閲覧またはダウンロードできます。Dell S4048-ON 29 ページ。 Enterprise switches
Dell S4048-ON にも: 設定マニュアル (19 ページ), 設定マニュアル (30 ページ)

Dell S4048-ON トラブルシューティングマニュアル
+ Checking Dev found @ 0x49 ...
+ Checking Dev found @ 0x4a ...
+ Checking Dev found @ 0x4c ...
+ Checking Dev found @ 0x4d ...
Checking I2C devices on bus 2:
I2C Devices: Overall test results --------------------- >>> Passed
Testing Programmable Devices:
PL Tool test:
+ Checking
System CPLD
+ Checking
System CPLD
PL Tool: Overall test results ------------------------- >>> Passed
Power Supply Test all
Power Supply 1 ............................................ Passed
Power Supply 2 is not present
Power Supply Test ......................................... Passed
Testing Temp sensor
+ Checking [CPU sensor]
+ Checking [MAC sensor]
+ Checking [Phy Right sensor]
+ Checking [Phy Left sensor]
Temp Sensors: Overall test results -------------------- >>> Passed
Fan Controller Short Test ................................. Passed
Fan 1
speed is 12240 RPM
Fan 2
speed is 12240 RPM
Fan 3
speed is 12240 RPM
Fan 4
speed is 12240 RPM
Testing Memory Regions:
Testing Memory Region 0:
Address Read Test ......................................... Passed
Address Write Test ........................................ Passed
Address Walking 1's Test .................................. Passed
Address Walking 0's Test .................................. Passed
Data Read Test ............................................ Passed
Data Write Test ........................................... Passed
Data Walking 1's Test ..................................... Passed
Data Walking 0's Test ..................................... Passed
Data Sliding 1's Test ..................................... Passed
Data Sliding 0's Test ..................................... Passed
Data Pattern Test ......................................... Passed
Memory: Overall test results -------------------------- >>> Passed
EDA: Overall test results ----------------------------- >>> PASSED.
The EDA tool tests the platforms using the default_eda_script.cfg configuration file. This script dictates how EDA runs and which test runs
first or multiple times. Each line of the script is the actual prompt command line including parameters.

pcitool

The PCI tool (pcitool) allows testing of the PCI devices.
In EDA Quick Test mode, pcitool completes a simple check on the PCI bus. The tool scans the PCI bus for all drivers and functions and
writes the configuration registers to the configuration file.
Example of the pcitool Output
Syntax: ./pcitool <option>
show <bus# dev# func#> := show config data for a specific bus:dev.func
read <bus# dev# func# offset count> := read 8-bit config register for bus:dev.func
write <bus# dev# func# offset data> := write 8-bit config register for bus:dev.func
------
------
------
------
0xffdf0000 Reg: 0x10 .................... Passed
0xffdf0000 Reg: 0xa0 .................... Passed
devices:
= 31.0 C ....................... Passed
= 38.0 C ....................... Passed
= 40.0 C ....................... Passed
= 38.0 C ....................... Passed
-h := show this help
scan := scan all PCI devices
all := scan and show all config data
test := test using the default PCI test config file
------ 0x49
..... Passed
------ 0x4a
..... Passed
------ 0x4c
..... Passed
------ 0x4d
..... Passed
ONIE diagnostics
13