ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician familiar with local legislation and standards.
• Protection against the parts under tension must be ensured after the installation.
• The data for connection is located on the stickers on the hob casing near the connection
box.
• The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
Caution!
This appliance has only to be connected to a network 220-240 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover.
Mains
220-240V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 220-240V~1P+N
Put a bridge between terminals L1 and L2 and between terminals N1 and N2.
Attach the earth to the terminal "earth", the neutral N to one of the terminals N1 or N2, the Phase
L to one of the terminals L1 or L2.
Biphase
400V~2P+N
Put a bridge between terminals N1 and N2.
Attach the earth to the terminal "earth", the neutral N to terminals N1 or N2, the Phase L1 to the
terminal L1 and the Phase L2 to the terminal L2.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 V2V2 - F
H 05 V2V2 - F
19
Protection calibre
25 A *
16 A *