Technical Information
Function
Final rinse temperature
modification (ID nos. -984
and later)
Program running time
reduction
(ID nos. -984 and later)
Water quantity
normal/increased
(ID nos. -876 and later)
Soak activation/
deactivation
Pre-wash
activation/deactivation
Second interim rinse (ID
nos. -984 and later)
Programming
Press the Delay Start
button 21x. The "Delay
Start" LED flashes 2x
slowly and once quickly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 22x. The "Delay
start" LED flashes 2x
slowly and 2x quickly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 23x. The "Delay
Start" LED flashes 2x
slowly and 3x rapidly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 24x. The "Delay
start" LED flashes 2x
slowly and 4x quickly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 25x. The "Delay
Start" LED flashes 2x
slowly and 5x quickly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 26x. The "Delay
Start" LED flashes 2x
slowly and 6x quickly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
34
G 1xxx/G 2xxx
Display
The "Rinse" LED is out or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Wash
temperature increased. If this option
is selected, the final rinse
temperature is increased and, as a
result, the program duration is
extended.
The "Rinse" LED is out or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Program
running time reduction.
Temperatures are decreased and/or
hold times removed, so the program
running time is shortened.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately: p0 = Normal water
quantity (standard setting); p1 =
Increased water quantity. If
increased water quantity is
selected, approx. 16.7 fl.oz.
(500mL) more water is taken in
during each water intake cycle.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Soak not activated; p1 = Soak
activated.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Pre-wash not activated; p1 =
Pre-wash activated.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = With second
interim rinse.