- ページ 13
食器洗い機 Miele G 1202のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Miele G 1202 14 ページ。
Miele G 1202 にも: マニュアル (46 ページ)
G 1xxx/G 2xxx
1.10
Excella - G 2732
Initial requirements:
1. Close the door.
2. Switch off the appliance.
Accessing:
1. Press and hold the Start button.
2. Switch on the appliance.
3. Release the Start button when the display lights up.
4. Immediately press the Start button 3 times; on the 3rd time, hold it
pressed in until the display shows the first 3 positions (items).
Acknowledgement indicator:
The LEDs are all off and setting options are shown in the display.
Options:
Function
Check ID. no.
Fault code display
Fault code deletion
Component test
Operating hours check
LED test
Buzzer test
Table 10: Service Mode Summary, G 2732
Programming
Select ID no. Press OK.
Select Fault memory.
Press OK.
Select Fault memory.
Select the option Delete
fault with the cursor
buttons; confirm with OK.
Select Component with
the cursor buttons. Press
OK. Activation of the
individual components
V01 - V18 takes place via
the cursor and OK
buttons.
Select Operating hours
with the cursor buttons. To
return to the main menu,
press OK.
Select Controls. Select
LED test. To return to the
main menu, press OK.
Select Controls. Select
Buzzer test. To return to
the main menu, press OK.
13
Technical Information
Display
The display shows the ID numbers
of the BAE (selection-display) and
SLT (control-power) electronics.
The display shows the saved fault
codes. If multiple fault codes have
been registered, they are all shown.
Alternatively, the message No fault
is displayed. See the service
manual for a list of fault codes
In the display, the option Delete
fault memory? is shown along with
the saved fault codes.
The display lists the available
components and mini-program with
wiring diagram/short description.
The relevant test program starts
after 2 s (see the service manual).
The display shows the number
of operating hours.
All LEDs and the display light up.
Buzzer on.