- ページ 35

食器洗い機 Miele G 2 SeriesのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Miele G 2 Series 46 ページ。
Miele G 2 Series にも: マニュアル (14 ページ)

G 1xxx/G 2xxx
Function
Extended drying time
Appliance height setting
Model setting
Country setting

Table 24: Service Programming Mode, G 2420/G 243x

1
In machines with software version -876, run the update "Optimized cleaning of tea
residues in Sensor Wash program" (mat. no. 06471560). Modified threshold values will
improve the cleaning outcome.
2
If the electronic needs to be replaced during servicing, the following steps must be taken
during programming: In the first step, set the country specification and model, then switch
off the appliance. Repeat access and then set appliance width and height, and the
appropriate supply water hardness.
3
The SER country specification includes the following countries: Portugal, France, the
Netherlands, Belgium and Great Britain.
Save and quit:
Switch off the appliance.
Programming
Press the Delay Start
button 27x. The "Delay
Start" LED flashes 2x
slowly and 7x quickly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 36x. The "Delay
Start" LED flashes 3x
slowly and 6x quickly
2
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 38x. The "Delay
Start" LED flashes 3x
slowly and 8x quickly
2
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
Press the Delay Start
button 39x. The "Delay
Start" LED flashes 3x
slowly and 9x quickly
2
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
35
Technical Information
Display
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Normal drying time; p1 = Extended
drying time (+10 mins).
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options:
p0 = Normal machine height (G
1xxx); p1 = XXL model (G 2xxx).
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Individual setting
possibilities depend on model
and whether a circulation pump with
slide shutter (WAW) and sensor
softener (SEH) are installed as
follows: p3 = G14xx, G24xx (without
WAW, with SEH).
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. The following
countries can be set: p1 = EUR
(Europe); p2 = AUS (Australia);
p3 = USA; p4 = JPN (Japan); p5
= I/E (Italy/Spain); p6 = SER
3
(Southern Europe).