コントロールユニット Allmatic BAXS900LのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Allmatic BAXS900L 13 ページ。 For rolling shutters
EXAMPLE OF CONNECTION MOLEX R.CO.O (RADIO SYSTEM T.CO.O - R.CO.O)
WARNING! When using R.CO.O with plug-in connector, set the jumpers at 8k2, the power supply jumper at
24V and DIP1 ON. It is necessary to learn the transmitter (T.CO.O, mobile part) to the receiver. To learn the
transmitter, briefly press the red "Prog/Reset" button on R.CO.O and then transmit with the T.CO.O button (Fig.7).
Fig. 7
EXAMPLE OF SPECIAL CONFIGURATION
CONNECTING THREE BAXS900 FOR SYNCHRONISED CONTROL VIA A SINGLE KEY SELECTOR
BAXS900 1
KEY SWITCH
WARNING! In the terminal block (see detail fig. 2) terminals 1-2 and 6 (COM) there are two clean contacts N.A.
(NORMALLY OPEN AND CLOSED INPUTS), from which it is possible to control the activation of other devices.
4 / 12
CONNECTOR
BAXS900 2
-
+
RESISTOR
8k2
1/4W
+
-
BAXS900 3
EDGE
CONTACT
N.C.
Fig. 8
6-1622623 rev. 3