- ページ 14

換気フード Miele DA 1160のPDF 操作およびインストール手順をオンラインで閲覧またはダウンロードできます。Miele DA 1160 32 ページ。 Built-under ventilation hood
Miele DA 1160 にも: インフォメーション (4 ページ), 操作およびインストール手順 (32 ページ), 操作およびインストール手順 (40 ページ)

Miele DA 1160 操作およびインストール手順
Cleaning and care

Changing the light bulbs

,WARNING
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Before changing the light bulbs,
disconnect the hood from the power
supply, see "Important Safety
Instructions".
When in use halogen bulbs become
extremely hot, and can burn your
hands. Do not attempt to change the
bulbs until they have had sufficient
time to cool.
14
^ Remove the grease filter.
^ Loosen the light fastening screw
slightly.
^ Slide the screw and the light down.
^ Fasten the screw again.
^ Turn the light counterclockwise and
pull it out.
Replace it with a light of the same type:
GU/GZ 10, 120 V, 50 W.
^ Install the new light in the reverse
order.
^ Put the grease filter back in place.