- ページ 34

換気フード Miele DA 220-4のPDF 操作およびインストール手順をオンラインで閲覧またはダウンロードできます。Miele DA 220-4 40 ページ。 Ventilation system
Miele DA 220-4 にも: 操作およびインストール手順 (36 ページ), 寸法マニュアル (2 ページ)

Miele DA 220-4 操作およびインストール手順
Air extraction
– If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
34

Condensate trap

optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and 6"
(150 mm) in diameter.
^ When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.