- ページ 6
換気フード Miele DA 372 EXTのPDF 操作および設置マニュアルをオンラインで閲覧またはダウンロードできます。Miele DA 372 EXT 32 ページ。 Cooker
The minimum safety distance
between the top of the cooker/hob
and the bottom of the cooker hood
should be at least:
– 450 mm above electric hobs and
cookers,
– 650 mm above gas hobs and
cookers,
– 650 mm above an open grill
from our range.
For non-Miele cooking appliances,
maintain the safety distance as
recommended by the manufacturer in
their Installation and Operating
instructions.
If more than one appliance is fitted
beneath the cooker hood, and they have
different minimum safety distances to the
cooker hood, select the greater distance.
Safety regulations prohibit the
fitting of a cooker hood over solid
fuel stoves.
All ducting, pipework and fittings
must be of non-flammable material.
These can be obtained from the Miele
Spare Parts department or from
builders' merchants.
The appliance must not be
connected to a chimney or vent
flue which is in use. Neither should it be
connected to ducting which ventilates
rooms with fireplaces.
If exhaust air is to be extracted into
a chimney or ventilation duct no
longer used for other purposes, seek
professional advice.
6
Warning - danger of toxic fumes
Great care should be taken when
using the cooker hood at the same
time and in the same room or area of
the house as another heating appliance
which depends on the air in the room.
Such appliances include gas, oil, wood
or coal-fired boilers and heaters,
continuous flow or other water heaters,
gas hobs, cookers or ovens which draw
air in from the room and duct exhaust
gases out through a chimney or
extraction ducting.
When used in exraction mode and also
when an external motor is fitted, the
appliance draws air in from the room in
which it is installed
neighbouring rooms.
If there is insufficient air, an
underpressure will occur. The heating
appliance may be starved of oxygen,
impairing combustion.
from