- ページ 20
換気フード Miele DA 5490 WのPDF 操作および設置マニュアルをオンラインで閲覧またはダウンロードできます。Miele DA 5490 W 36 ページ。 Cooker hood
Appliance dimensions
1) Extraction
2) Recirculation
3) Ventilation grille positioned at the top
for recirculation
4) and 5)
The shaded areas represent the wall or
ceiling area for the vent cut-out and for
fitting the connection socket.
For recirculation mode, you only require
cut-out area 4) and a connection
socket.
Connection for air extraction
C 150 mm, or C 125 mm with reducing
collar.
20
Safety distance between hob and
cooker hood (S)
When planning the installation height
of your cooker hood, the minimum
safety distance between the top of a
cooker or hob and the bottom of the
cooker hood are as follows, unless a
greater distance is specified by the
manufacturer of your cooking
appliance:
450 mm (GB), 600 mm (AU, NZ)
above electric hobs and cookers,
650 mm above an open grill or deep
fat fryer,
650 mm above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety" instructions
for further information.