a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (only d is required for recirculation mode cooker hoods): The shaded area
represents the wall or ceiling area for the vent cut-out, for fitting the
connection socket and on EXT models for feeding the connection cable
through to the external motor. Recirculation mode cooker hoods only require
an electrical connection socket.
Existing tiling or a back panel behind the cooker hood can make it difficult to
remove the grease filter. If this is the case turn the filter by 180° to fit it .
Connection for air extraction 150 mm, or 125 mm with reducing collar.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker
hood is as follows, unless a greater distance is specified by the manufacturer of
your cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill
Deep fat fryer (electric)
Multi-burner gas hob with a maximum total output of
12.6 kW, no burner exceeding 4.5 kW.
Multi-burner gas hob with a total output of more than
12.6 kW, or a multi-burner gas hob where one burner
exceeds 4.5 kW.
Single gas burner with a maximum output of 6 kW.
Single gas burner with output exceeding 6 kW.
Installation
Minimum distance S
450 mm
650 mm
650 mm
650 mm
760 mm
650 mm
760 mm
27