- ページ 27
換気フード Miele DA 6086 WのPDF 操作およびインストール手順をオンラインで閲覧またはダウンロードできます。Miele DA 6086 W 40 ページ。 Cooker hood
Miele DA 6086 W にも: 操作およびインストール手順 (44 ページ), 操作およびインストール手順 (45 ページ)
a Ducting upwards or to the rear
b Cut-out for cooker hoods with hard-wired connection rather than a plug
c A ducting outlet with 200 mm ensures sufficient space through the wall for
the ducting to flex
d Ventilation grille for recirculation mode. The distance to the ceiling or to
furniture installed above the appliance should be at least 300 mm.
Vent connection 150 mm
Please observe the installation positions for the socket and for the ducting outlet
shown on the relevant drawings when using the DADC 6000 tower.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill, deep fat fryer (electric)
Multi-burner gas hob,
total output ≤ 12.6 kW, no burner > 4.5 kW
Multi-burner gas hob,
total output > 12.6 kW and ≤ 21.6 kW,
no burner > 4.8 kW.
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Single burner gas hob, output ≤ 6 kW.
Single burner gas hob, output > 6 kW and ≤ 8.1 kW.
Single burner gas hob, output > 8.1 kW
Installation
Minimum distance S
450 mm
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible
27