command given by the user is received (S.S., CLOSE, etc).
8.2 PHOTO AUTORECLOSE
The gate closes 3 seconds after the photocell intervenes in case the gate is in a totally open or in a pedestrian open position.
8.3 MOTOR BRAKE
Electronic braking function to be used with motors with a strong inertia and the necessity to quickly stop the automation. Pay attention as the
mechanics must be sized accordingly.
8.4 Dead Man
The motor moves only with permanent a command and not with just impulses: the motor opens if the key "open" is kept pressed, and the opposite
operation applies with the key "close". WARNING: this modality forbids all operations of automatic motion!
8.5 Condominium
All commands given via radio or by a step-by-step and/or a pedestrian keys involve only the opening of the gate. The closing is related to the function
of automatic closing, which MUST BE ABSOLUTELY ACTIVATED since every command of closing is ignored.
8.6 Inv. On photocells
Allows to set if, once the photocell beam is interrupted, the gate must reverse immediately (only in closing) or just after the removal of the obstacle (it
applies both in opening and in closing)
8.7 Photocell test
This control unit is equipped with a function which allows to control the proper functioning of photocells before any operation of the motor is made. The
security of the system is therefore higher in case the photo-device breaks down (for example, if the relay of exit is stuck) or there is a undesired short
circuit on the input of the photocells. The control board indicates a possible fault by flashing only once when any key is pressed and also by not moving
at all. This check is made after the control board receives a command to move, but before the control board itself gives power to the motor.
8.8 Edge Inv.
Allows to set if, once the safety edge alarms itself, the gate must stop or it must stop and then reverse (applies only in the phase of closing).
8.9 Test Costa
Test funzionale della costa. Collegare la costa come indicato nelle istruzioni utilizzando il morsetto di alimentazione TX Photo.
8.10 Edge Test
Functional test of the safety edge. Connect the safety edge as shown in the instructions by using the photocell test's clamp.
8.11 Area light
Possibility to use the auxiliary light output as courtesy light, or as area light (it stays on until the gate is closed).
8.12 Auxiliary light timeout
There is the possibility to set the delay of switching-off of the auxiliary light after the automation stops
8.13 Clock function
Input OPEN becomes input clock in case it is possible to connect a timer for the programmed opening of the automation. The contact is understood
as a command to opening and to stay open as long as this status stays closed. When the contact is opened, then the unit reset its normal functioning,
waiting for a command given by the user (if the automatic closing is required, then it must be enabled from the menu).
8.14 Water hammer in opening
If the automation is equipped with an electronic lock, then it is advisable that, when the gate is closed, the motor shortly operates in closing before it
starts the opening phase (water hammer). This function allows to unlock the electronic lock in any case, even when the weather conditions are very
bad (for example in case of ice). The activation of this function enables also the electronic lock's output.
8.15 Encoder (optional)
If the motor is equipped with a suitable encoder, then it is possible to enable the functionalities of the encoder. In such way the control board does not
work any longer "by time" but "with encoder" instead. It is possible to detect the possible blocking of the motor.
8.16 Sensor level (optional)
If it is enabled, it allows to modify the intervention sensitivity of the "stop motor" sensor. Decrease the value that is set in order to have higher
sensitivity. If the sensitivity is too high and the sensor operates without any apparent reason, then increase the value
8.17 Sensor inversion (optional)
Allows to define the reaction of the gate in case the "stop motor" sensor applies. If the reversing is not activated, then the gate stops and waits for a
new command. If the reversing is activated, then the gate reverses shortly in case the sensor applies during the opening; it open completely in case the
sensor applies during the closing phase of the gate.
8.18 RESET of the control unit (Menù C - Reset)