- ページ 19

ドライヤー Miele T 1520iのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Miele T 1520i 32 ページ。 Vented dryer

Miele T 1520i 取扱説明書
Grounding instructions
This appliance must be grounded.
In the event of a malfunction, ground-
ing will reduce the risk of electric shock
by providing a path of least resistance
for the electric current. This appliance
is equipped with a cord having an
equipment grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet that
is properly installed and grounded in
accordance with all local codes and or-
dinances.
Warning
Improper connection of the equip-
ment-grounding conductor can re-
sult in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded.
Do not modify the plug provided
with the appliance; if it will not fit the
outlet, have the proper outlet in-
stalled by a qualified electrician.
INSTALLATION INSTRUCTIONS
Grounding and Electrical connection
Electrical connection
This installation should be done by an
experienced and qualified person, in
most cases a licensed electrician, in ac-
cordance with local codes and regula-
tions.
This dryer is supplied with a 5 ft long,
12/4 AWG cord and a NEMA 14-20 P plug.
It should be connected to a 120/240 V
(208 V), 60 Hz AC power supply.
A 3 pole-4 wire grounding receptacle is
needed. (NEMA type 14-20 R).
"EASY INSTALLATION KIT"
If you do not have a dedicated 15 Amp
line for this appliance, but you have the
standard 3 wire, 240 V - 30 Amp outlet,
you can use the "Easy Installation Kit",
which allows you to use that line to con-
nect this appliance.
For more information on the electrical
connection and the "Easy Installation
Kit" please contact
– the nearest Miele Service Depart-
ment.
19