Pressure regulator
A pressure regulator convertible to Natural
and LP Gas (Liquefied Petroleum) is
included with the appliance.
Conversion is carried out by inverting
the regulator cap marked "NAT"/"LP". If
"NAT" is visible then the regulator is set
for Natural gas and if "LP" is visible then
it is set for Liquefied Petroleum Gas.
Nominal rating for all types of gas
(USA/CDN)
Maximum output . 4.25 kW 14500 Btu/h
Minimum output . . . . . 0.2 kW 680 Btu/h
For USA only
The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
National Fuel Gas Code,
ANSI Z 223.1.
Gas Pressures for USA:
Max. Supply Pressure: 1/2 PSI
Manifold pressure:
– Natural gas 4" water column
– Propane gas 10" water column
Min. Supply Pressure:
– Natural gas 5" water column
– Propane gas 11" water column
Gas connection
For CDN only
The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
current CAN/CGA B 149.1 and .2
Inst.
Gas Pressures for CDN
Manifold pressure:
– Natural gas 4" water column
– Propane gas 10" water column
Min. Supply Pressure:
– Natural gas 5" water column
– Propane gas 11" water column
Gas connection