- ページ 18

クックトップ Miele KM 363 GのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Miele KM 363 G 28 ページ。 Gas hobs
Miele KM 363 G にも: 取付説明書 (24 ページ), 取付説明書 (28 ページ)

Miele KM 363 G 取付説明書
Gas connection

Setting the gas pressure

The gas pressure must be set by the
approved gas fitter as shown on the
data plate:
Natural gas 1.0 kPa
ULPG (Propane/Butane) 2.75 kPa
The gas pressure must be set with the
largest burner operating at maximum
setting.
For ULPG models
a Connection R ¹/₂" with test point
b Connection R ¹/₂" with test point and
90° angle
When using a 90° angle the building-
in depth will increase to the depth of
the elbow used.
18
For Natural gas models
The gas regulator is only included with
appliances which are set up for
connection to natural gas. The
regulator must be connected directly
to the applinace.
a
a Pressure Test Point
 Loosen the screw in the test point
 Connect the hose from the pressure
b
 Reassemble one of the large burners,
 Disconnect gauge and screw in the
a
until it is free in its housing. The
screw is retained in this position.
gauge.
turn on the gas and manually light the
burners.
test point screw.