- ページ 27

溶接システム Miller FieldPro Feeder CEのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Miller FieldPro Feeder CE 44 ページ。 With weld cable control

Miller FieldPro Feeder CE オーナーズマニュアル
Display Amperage − Set switch 2 so the depressed section is toward OPEN as labeled on the switch.
Wire Speed / Amps Display will display Amps while welding and Wire Speed while not welding. If the hold function
is enabled, Amps will be displayed during hold also.
Do Not Display Amperage (Factory Default) − Set switch 2 so the depressed section is toward 2 as labeled
on the switch.
Wire Speed / Amps Display will display only Wire Speed.
Wire Speed - Meters Per Minute − Set switch 3 so the depressed sections are toward OPEN as labeled on the
switch.
Displays Wire Speed in Meters per Minute.
Wire Speed - Inches Per Minute − Set switch 3 so the depressed sections are toward 3 and 4 as labeled on the
switch.
Displays Wire Speed in Inches per Minute.
No Wire Feeding While Association OFF (Factory Default) − Set switch 4 so the depressed section is toward
4 as labeled on the switch.
This will allow wire to feed when the trigger is pulled and association is not expected to take place, such as when
using the feeder with a non−WCC power source or if a WCC power source is to be used in the STICK process
with the feeder CC/CV switch in CC.
No Wire Feeding While Association ON − Set switch 4 so the depressed section is toward OPEN as labeled
on the switch.
This will prevent wire from feeding while the process of association takes place.
Display Feeder Information − Set switch 5 so the depressed section is toward OPEN as labeled on the switch.
With switch in ON position, at feeder power up, feeder will display various sets of information. Each set of informa-
tion will be displayed for three seconds.
Display Board (PC22) Software Part Number −
Top display will show the first three digits, bottom display will show last three digits of the Display board (PC22)
software revision level.
Motor Board (PC1) Software Part Number −
Top display will show the first three digits, bottom display will show last three digits of the Motor board (PC1) soft-
ware revision level.
Accumulated Weld Time −
This is the time the feeder has actually been used for welding. This information will be displayed in two halves.
First being years and days, second in hours and minutes. Top display will show years/hours, bottom display will
show days/minutes.
Do Not Display Feeder Information (Factory Default) − Set switch 5 so the depressed section is toward 5 as
labeled on the switch.
Feeder information is not displayed.
Ref. 805 200-B