- ページ 22
溶接システム Miller XR-W AlumaPro Plus 25 ftのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Miller XR-W AlumaPro Plus 25 ft 36 ページ。 Ce and non-ce models air and water-cooled guns; 250 ampere (air) push-pull; 300 ampere (air) push-pull; 400 ampere (water) push-pull
![Miller XR-W AlumaPro Plus 25 ft オーナーズマニュアル](/uploads/products/server2/3571360/3571360.png)
7-2. Cleaning The Gun Liner On XR-AlumaPro Plus Guns
5
6
5
OM-245892 Page 18
1
2
4
4
3
Gun End
Power Pin End
7
8
Power Pin End
!
Turn Off welding power
source and wire feeder.
NOTICE − Clean gun liner be-
fore cleaning stainless tube and
inlet guide.
Lay gun cable out straight.
1
Leather Cover
Remove leather cover to ac-
cess liner assembly.
2
Liner Guide Reducer
3
Liner Lock Allen Screw
4
Power Pin
5
Air Nozzle
Loosen liner lock allen screw
(located near back of handle) to
remove liner guide reducer from
gun.
Blow air from power pin end
through liner until clean of
debris.
Reinstall liner assembly into
gun and firmly tighten (do not
overtighten) liner lock allen
screw when finished cleaning.
NOTICE − Do not overtighten
liner lock allen screw.
6
Top Cover
7
Set Screw (Inlet Guide)
8
Inlet Guide
Remove inlet guide. From pow-
er pin end, blow air through liner
and stainless tube until free of
debris.
Reinstall inlet guide.
Ref. 246 348-A / 804 544-B