Technical data
5.
TECHNICAL DATA
5.1. Conformity
The system AirLINE type 8644 conforms with the EC Directives
according to the EC Declaration of Conformity.
5.2. Standards
The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.
5.3. General Technical Data
Technical Data
Pilot valve type 0460,
6524, 6525
Pressure range
Vac. up to 10 bar
Operating
24 V DC
voltage
Voltage tolerance +20 % / -15 %
(when using
Type 0460: ± 10 %)
Ambient
0 ... +55 °C
temperature
(when using Type 0460 and 0461: 0 ... +50 °C)
Type 8644
Pilot valve type 0461,
6526, 6527
Vac. up to 10 bar
24 V DC
+20 % / -15 %
(when using
Type 0461: ± 10 %)
5.3.1. Rating plate
6525 H 4,0
PN 2,5 - 7 bar
24 V DC 1W
450000Y
Identification number
Voltage (±10 %), capacity
Pressure range
Fig. 1:
Location and description of the rating plate
english
Type
Operating principle
Orifice
W14UN