General safety requirements
`
`
Read these directions for use carefully before using.
`
`
Keep these directions for use where they will be
accessible for all users.
`
`
Failure to comply with the directions for use shall
render all warranty conditions null and void and
may lead to personal injury and material damage.
`
`
The instrument must only be used by qualified
skilled employees.
Safety instructions before using
`
`
Follow the manufacturer's instructions and safety
instructions of the medium you are sampling.
`
`
When sampling hazardous substances, follow
the technical rules on hazardous substances (in
accordance with TRGS – (German) Technical Rules
on Hazardous Substances) and wear appropriate
protective equipment.
`
`
The instrument must only be used within the
confines of applicable material resistance and for its
designated purpose. Any other type of use will affect
the warranty/guarantee.
`
`
Do not use any force when operating the instru-
ment.
WARNING!
Damage to the respiratory tract and other organs
due to escaping or outgasing media.
`
`
When sampling hazardous substances, follow
the safety data sheet of the medium to be
sampled.
`
`
Wear the appropriate protective clothing.
NOTE!
Before using, the instrument has to be cleaned to
the extent of your (validated) cleaning process.
`
`
Measures of manual cleaning have to be carried
out in the cleaning/desinfection area and under
consideration of occupational health and safety.
`
`
Pay attention to the material resistance.
Safety instructions during and after use
`
`
The device can be used in the temperature range of
0 - 60 °C.
`
`
Pay attention to have sufficient space above during
the application (minimum height: height of the
sampler + 50 cm).
Layout and function
`
`
The instrument is made of stainless steel 1.4404/
AISI 316 L.
`
`
The instrument is suitable to take bulk goods
samples from silos.
`
`
Using the extension rods (see accessories), samples
can be taken from depths down to a maximum of
3.50 m.
`
`
The insertion depth depends on the density of the
bulk goods.
`
`
The instrument is maintenance-free and suitable for
steam sterilisation (up to 121°C).
Parts in contact with medium
`
`
Stainless steel 1.4404/AISI 316 L
Scope of delivery
1 x
Sample container
1 x
Extension rod, 100 cm
1 x
Handle
1 x
Directions for use
`
`
Check delivery for completeness and transport
damage.
`
`
Point out any damage in the packaging to the
freight forwarder/supplier immediately.
Assembly
CAUTION!
Moving parts on the instrument. Risk of crushing.
`
`
Keep hands well away from moving parts.
1. Screw the handle  onto the extension rod .
2. If necessary, screw on additional extension rods (see
accessories). Maximum permissible length: 3.50 m.
3. Screw the sample container  onto the extension
rod.
NOTE!
Possible loss of the sample container during use.
`
`
Screw the sample container tightly onto the
extension rod.
`
`
Verify that the sample container is attached
correctly before use.
`
`
Do not rotate the instrument while plunging
into the medium to be sampled.