Rinsing of the pre-treatment and conditioning unit
• Set the input tap to the Open.
• Open the tap for fresh water and wait for water to flow from it. First, air
will escape from the system, which may be accompanied by noise.
• Pass water through the water purifier for 10 minutes.
• Close the fresh water faucet and allow the water cleaner to sit for
10 minutes.
• Close the input faucet
Table 1. The position of the cartridges in the RO-70S for the
preparation for operation
Color of the lock button
BLACK
RED
• Flow water again through the water purifier for 30–50 minutes
Step 3. Install the RO-50S membrane cartridge
• In accordance with Table 2, insert each cartridge into the corresponding
manifold until it stops and turn it clockwise until it clicks (fig. 11a).
• Connect the drain pipe bracket to the replacement membrane cartridge
(for this, insert the pre-wetted end of the square into the drainage sleeve
bushing to the stop, see fig. 11b). Install the locking clip.
Table 2. Position of cartridges in RO-70S
Color of the lock button
BLACK
RED
Step 4. Rinse the RO-70S
Rinsing of reverse osmosis membrane unit
• Set the input tap on the connection node to the Open position.
• Open the faucet for fresh water. Wait for water to flow from it.
• Run water through the RO-70S for 1 hour.*
• Close the fresh water faucet.
Flush the storage tank
• After filling the storage tank (when the water stops coming out of the drain pipe), open the fresh water
faucet and wait until all the water has drained out of the storage tank.
• Refill and drain the storage tank.
Note: the procedure for filling the tank twice takes no more than 3 hours.
• Ensure that the RO-70S is sealed.
• After filling the tank, the RO-70S is ready for operation.
ATTENTION! The water obtained during rinsing is not intended for drinking!
Check the RO-70S for leaks during the first week of operation.
In the first week of operation of the RO-70S, when the automatic valve is switched, noise may be observed
associated with the release of air from the internal cavities of the RO-70S. After a while, this process will stop.
This is not a malfunction.
Depending on the conditions of storage, transportation and operation, the complete rinsing of the
membrane cartridge can take no more than 24 hours.