- ページ 15

エアコン Panasonic 2008のPDF パンフレット&スペックをオンラインで閲覧またはダウンロードできます。Panasonic 2008 17 ページ。 Panasonic air conditioner brochure

Wide & Long Airflow Vane
This newly designed vane has been
integrated with the louver to send the air
further. Sends air to every
corner of the room to
keep the whole room
comfortable.
Wide & Long Airflow Vane
Conventional
Below 20
c
o
Conditions: . Our simulated-house facility 13.2m
2
. Set temperature 25°C
Personal Airflow Creation
Vertical and horizontal air flow patterns
can be combined as desired to gain the
greatest possible comfort, with
operation possible even from a distance
by remote control.
• Up & Down Airflow —
5 Patterns + Auto
When you don't want
When you want direct
When you want to
airflow directed right
airflow.
warm yourself
at you.
thoroughly from the
feet up.
• Left & Right Airflow —
5 Patterns + Auto
To focus the airflow to
To focus the airflow to
For uniform airflow
one side of the room.
the centre.
throughout the room.
ISO 9001 Certification
CERTIFIED TO MS ISO 9001: 2000
Panasonic HA Air-Conditioning (M) Sdn.
Bnd. (PHAAM)
Registration No.: AR 1010
This Panasonic air conditioner factory in Malaysia has received
ISO 9001 certification. ISO 9001 Certification attests to the
excellent quality assurance systems in place at this factory.
About ISO 9001 Certification
ISO 9001 certification is granted only when thorough
examination has shown that products are designed,
manufactured, marketed and serviced by a system of quality
that is complied with the internationally recognized ISO 9001
quality assurance standard. The Malaysian factory was
certified by the world renowned SIRIM organization.
Auto Changeover (Inverter)
Auto Changeover
Auto Changeover System
Checks three temperatures.
Set
temperature
Evaluates the three temperatures
and selects the operating mode
Below 20
c
o
Heat
Hot Start Control
On the start of heating cycle and after
defrost cycle, the indoor fan will start up
once the indoor heat exchanger is warm.
Airflow Direction Control
(Up & Down)
Manual Horizontal Airflow
Direction Control
Soft Dry Operation Mode
Starts with cooling to dehumidify.
Then provides continuous breeze at low
frequency to keep room dry without
much change in temperature.
Convenient
24-Hour ON & OFF Real Setting Timer
The start or stop operation time (hour
and minute) can be set at one time.
Or both of the times for start and stop
operation can be set.
LCD Wireless Remote Controller
Environmental Management
Systems Approval
Certificate
ENVIRONMENTAL
SYSTEM
SIRIM
MS ISO 14001 CERT. NO. P06860001
CERTIFIED TO MS ISO 14001: 2004
Panasonic HA Air-Conditioning (M) Sdn.
Bnd. (PHAAM)
Certification No.: P06860001
Room
Outdoor
temperature
temperature
Every period
accordingly.
Dry
Cool
* at "AUTO" operation
074
Reliable
Blue Fin Condenser
Condensers can take a beating from exposure
to salty air, rain and other corrosive factors.
Panasonic has tripled the life of our condensers
with an original anti-rust coating.
Special Coating Layer
(Fin Cross-section)
Water Air
Base material
Cyclic Corrosion Test Results
Blue Fins
Non-Blue Fins
Front View
Side View
This was tested by:
1. Matsushita Air Conditioning R&D Centre Sdn. Bhd.
2. A third party authorized research institute in Malaysia.
Random Auto Restart
All models are now safe to operate without a
starter. With the exclusive Random Auto Restart
feature, the air conditioners automatically restart
after power failure. Its 32 different recovery-timing
patterns ensure that air conditioners in the same
building resume one after another instead of all at
the same time. This feature helps prevent power
surges after a blackout and walls are nearer too.
Long Piping
The basic piping can be extended,
allowing the outdoor unit to be installed
farther away from the
indoor unit and
providing greater
installation flexibility.
*The graph refers to the CS-E28GKR *Extendable length varies
by model. *If the piping is extended past the basic pipe length,
there's an extra charge for additional refrigerant.
Top-Panel Maintenance Access
Maintenance of the outdoor unit used to be quite a
tedious chore, especially when the unit was
installed on a narrow balcony or attached to the
outer wall of a high-rise building.
Self-Diagnostic Function
Should a malfunction occur, the unit diagnoses
the problem and shows the corresponding
alphanumeric code. This allows quicker servicing.
Not all features found on all models.
Standard Warranty
Salt
content
Corrosion-
resistant layer
Max. 30m
Pipe
length
Max. 20m
Level
difference
15