- ページ 8

浄水器 Aquaport AQP-FKM2のPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Aquaport AQP-FKM2 17 ページ。

Aquaport AQP-FKM2 据付・取扱説明書
B. Water Supply Installation
Preferred Installation
(Utilising existing kitchen sink water supply and flexible
faucet tubing)
A typical connection using the included water supply fitting is
shown on Page 5.
1 Locate cold tap water pipe and turn water supply off at the
isolation tap. If no isolation tap is available, turn off at the
meter. Turn on tap at sink to check and ensure water is turned
off and to drain the pipe.
2. Remove the flexible cold water hose that connects the cold
water faucet to the cold mains connection. Some water may
spill out.
3. Wrap sealing tape (6) around cold water stud in a clockwise
direction.
Note: Do not apply sealing tape in a counter clockwise direction, it
releases the sealing tape and leaks may occur.
4. Making sure that the washer is inserted correctly into the
female connection of the mains connection (5), hand tighten
the mains connection to the mains cold water stud (please see
Fig 1). Finish tightening with an adjustable wrench.
6 INSTALLATION AND OPERATING INSTRUCTIONS
Be careful not to over tighten, as cross threading and leaking
can occur. Make sure the shut off valve connection is not
against a wall as the 1/4" tubing must not be bent, see Page 5.
5. Wrap sealing tape (6) around male thread of mains connection
(5) in a clockwise direction.
6. Reconnect the flexible cold water hose to the mains
connection (5).
7. Install 1/4" tubing (3). (see tubing installation section D)
Note: Inspect the ends of the tubing
to be sure there are no imperfections
and that the end of the tubing is cut
square. It may be necessary to cut
the tubing again.
Note: Plumbing connections may
vary, please consult a qualified
plumber for correct installation
method for your home.
Fig 1
Flexible
Cold
Water
Tap
Hose
1/4" Tubing
to filtration kit
Mains Cold
Water Isolation
Outlet