- ページ 5
薪ストーブ Burley Fireball Brampton 9108のPDF 取付説明書&ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Burley Fireball Brampton 9108 20 ページ。
Burley Fireball Brampton 9108 にも: 取付説明書&ユーザーマニュアル (20 ページ)
TECHNICAL DATA
All built to EN13240
Efficiency (Net)
CO concentration
@ 13% Oxygen
Dry logs <20%
Requirement of fuels
Maximum length
used in Smoke
170 -220mm long
Control Areas
Maximum width
Lower quality fuel
can be used in non-
smoke controlled
areas, but will not
give the best
efficiencies
Weight in kg
Nominal kW output
Max kW output
Air vent requirement.
Minimum flue draught
mm H²O
Flue gas temperature
Spigot Temp.
Flue size (Top Exit)
Min. chimney
diameter
Best chimney
diameter
Minimum distance to
combustible
materials. All other
10cm behind (4")
distance as per
35cm at side (14")
Building regulations
Part J or HETAS
recommendations
Non combustibles
minimum distance; although we would advise a minimum of 50mm from any surface to allow for convection.
Max Hearth temp.
Min Hearth thickness
Springdale
Debdale
9103
9104
88.9%
89.8%
0.1%
0.1%
Dry logs <20%
H₂O
H₂O
Maximum length
200 -250mm long
Maximum width
150mm
150mm
Dry Logs
Dry Logs
< 25% H₂O
< 25% H₂O
220mm long
250mm long
45 kg
57 kg
3 kW
4 kW
4.1 kW
5.3 kW
Not Required
Not Required
0.5mm
0.5mm
162 °C
156 °C
258 °C
253 °C
127mm (5")
127mm (5")
127mm (5")
127mm (5")
127mm (5")
127mm (5")
20cm behind (8")
40cm at side (16")
35cm to Top
40cm to Top
When fitted inside a masonry or similar non-flammable material recess, e.g., fireplace opening, there is no
<100 °C
<100 °C
12mm
12mm
Hollywell
Brampton
9105
89.1%
0.1%
Dry logs <20%
Dry logs<20% H₂O
H₂O
Maximum length
Maximum length
250 -300mm long
250 -350mm lonG
Maximum width
Maximum width
150mm
Dry Logs
Dry Logs
< 25% H₂O
< 25% H₂O
310mm long
430mm long
95 kg
5 kW
6.4 kW
11.7 kW
550mm sq min in
houses built after
1,962mm sq min
2010, otherwise
50mm diameter
not required
Air vent not
Air vent not
required if stove is
required if stove is
room sealed
room sealed
0.5mm
122 °C
241 °C
150mm (6")
150mm (6")
150mm (6")
150mm (6")
150mm (6")
150mm (6")
20cm behind (8")
10cm behind (4")
35cm at side (14")
40cm at side (16")
35cm to Top
40cm to Top
<100 °C
<100 °C
12mm
Wakerley
9108
9112
85.5%
84.1%
0.1%
0.1%
Dry logs<20% H₂O
Maximum length
300 -450mm long
Maximum width
150mm
150mm
Dry Logs
< 25% H₂O
580mm long
105 kg
130 kg
8 kW
12 kW
18.3 kW
7,850mm sq min
100mm diameter
Air vent not
required if stove is
room sealed
0.5mm
0.5mm
183 ˚C
237 °C
274 °C
316 °C
150mm (6")
150mm (6")
175mm (7")
20cm behind (8")
45cm at side (18")
45cm to Top
<100 °C
12mm
12mm
Page 5 of 20