- ページ 7
配管製品 Burlington T30 CHRのPDF 組み立てをオンラインで閲覧またはダウンロードできます。Burlington T30 CHR 9 ページ。 High level flush pipe kit
Tighten the nut, connect the water supply to the cistern.
2: Filter cleaning (Please clean periodically)
Turn off the water supply, screw off the water supply pipe.
3:
Inlet Valve trouble shooting
Problem
Incorrect water level
Incorrect adjustment.
Water supply is closed.
Inlet Valve does not work
The filter is blocked.
The Stop Float has been over adjusted beyond its operational range.
The Inlet Valve fixing nut has not been tightened.
Leakage
Pull out the filter from the Inlet valve.
Reason
Note:
To ensure the full flushing volume of 6.0 litres, and the half flushing
volume of 3.0 litres. We suggest you adjust the height from top of the
adjustment rod to the stop float to be 60mm.
Filter
Clean by rinsing the filter.
Solution
Adjust the Water level correctly as per diagram above.
.
Open the water supply
Clean the filter.
Adjust the adjustment rod.
Tighten the nut.
3 - 5
Adjustment the rod:
A: By adjusting clockwise the
water level rises and flush
volume increases.
B: By adjusting anti-clockwise
the water level falls and the
flush volume decreases.
Reinstall the filter and the water supply pipe.
C