1.2. INSTRUCTIONS FOR REPLACING
COMPONENTS
(to be carried out only by a specialised
installer)
- Gas valve
• Remove the control panel, undoing the fixing screws.
• Unscrew the pilot burner pipe and thermocouple.
• Undo the screws fixing the flange to the valve.
• Remove the gas valve supply pipe clamping.
- Thermocouple, thermopile, safety thermostat, ignition
device
• Remove the control panel and replace the elements.
• To replace the thermostat, remove the gasket between
the tank and bulb clamping (replacement from door
compartment and control panel).
- Main burner, pilot burner, pilot nozzle and main nozzle.
• From the door compartment.
- Main air adjustment
• From the door compartment.
1.3 MAINTENECE SCHEDULE
• It is reccommended the appliance is inspected and
serviced by an authorized person at least every 12 months.
For this purpose it is reccommended to draw up a maintenece
contract.
AUSTRALIA
For service and spare parts, please contact:
Electrolux - Tom Staddart Pty Ltd
Zanussi - JL Lennard Pty Ltd