4.6
Troubleshooting
- Everything looks fine, but I get no gas :
Is your ventilation system on? Don't forget to turn it on.
NEVER ATTEMPT TO DISMANTLE OR REPAIR THE APPLIANCE YOURSELF!
DANGER OF DEATH !
- The pilot burner does not ignite :
Is the ignition spark adequate? If not, check whether the ignition cable has become disconnected. If necessary, light the
pilot burner using a match and have your lighting system replaced.
- The pilot burner ignites, but when I release the button (see the relevant description, after 10-15 seconds, the
flame goes out by itself :
Generally, this indicates a defective thermocouple component; you MUST HAVE IT REPLACED.
- My appliance keeps turning itself off :
Is your appliance properly connected? (There should be a minimum clearance of 15 cm above your exhaust chimney).
Could one of your tanks have become overheated? (The safety sensor is activated automatically). If one of your tanks
overheats, it is quite probable that the thermostat detector is defective. In this case, have it replaced right away.
Do not use this tank any more.
THE MAXIMUM SAFETY THRESHOLDS SET IN FACTORY CAN NEVER BE CHANGED OR TAMPERED WITH.
Your appliance has a rock-solid design and robustness, according to optimum safety manufacturing standard.
4.7
Fire safety
In the event of tank overheating, if the grease or oil catches fire, do the following :
Do not panic. Take the nearest lid and cover the burning tank. The fire will soon go out due to lack of oxygen.
The fryer is fitted with a safety device that turns off the appliance automatically at 210°
NEVER, EVER, USE WATER TO PUT OUT THE FIRE !!!
14