5. Current measurements
The Escola 30 is not permitted to be
used for measurements on low-volt-
age mains distribution equipment,
such as mains sockets, circuit breakers
and fuses etc.
The nominal voltage of the electricity
source must not exceed 30 V and its
nominal current must be no higher
than 3 A.
The multimeter is to be connected
in series with the load on the side
where the voltage with respect to
ground is lowest!
Turn off the circuit before the Es-
cola 30 meter is connected into it.
~
~
~
Connect the side with the lower potential to
the left-hand socket.
Connect the common/ground lead first and
only then the signal lead.
5.1 DC currents (mA=):
Set the rotary switch to the desired DC current
range. If measurements are made when the
magnitude of the variable is unknown, always
select a large measuring range before shifting
down to lower ones.
Set the three-way switch to
zero point is to be set in the centre, to
5.2 AC currents (mA~):
Set the rotary switch to the desired AC current
range. If measurements are made when the
magnitude of the variable is unknown, always
select a large measuring range before shifting
down to lower ones.
Set the three-way switch to
~
~
Connect the side with the lower potential to
the left-hand socket.
Connect the common/ground lead first and
only then the signal lead.
~
6.1 DC voltages (V=):
Set the rotary switch to the desired DC voltage
range.If measurements are made when the
magnitude of the variable is unknown, always
select a large measuring range before shifting
down to lower ones.
Set the three-way switch to
zero point is to be set in the centre, to
6.2 AC voltages (V~):
Set the rotary switch to the desired AC voltage
range.If measurements are made when the
magnitude of the variable is unknown, always
select a large measuring range before shifting
or, if the
down to lower ones.
.
Set the three-way switch to
Symbols for measuring ranges
mA= DC (unit mA)
mA~ AC (unit mA)
.
V=
V~
3
6. Voltage measurements
The Escola 30 is not permitted to be
used for measurements on low-volt-
age mains distribution equipment,
such as mains sockets, circuit breakers
and fuses etc.
The nominal voltage of the voltage
source must not exceed 30 V.
~
DC voltage (unit V)
DC voltage (unit V)
~
or, if the
.
.