- ページ 7

水ポンプ AquaScape AquaSurge 2000-4000のPDF 使い方とメンテナンスをオンラインで閲覧またはダウンロードできます。AquaScape AquaSurge 2000-4000 20 ページ。 Adjustable flow pond pump
AquaScape AquaSurge 2000-4000 にも: 使い方とメンテナンス (20 ページ)

AquaScape AquaSurge 2000-4000 使い方とメンテナンス
NOTE: Do not remove the outer or inner filter screens
while operating the pump, as failure to do so may cause
the pump to fail, voiding the warranty.
• The outer screen is designed to pop off when it is gently
pulled from either side (Ex. 15).
• The inner filter screen can be removed by unscrewing
counterclockwise (Ex. 16).
NOTE: Be sure to replace the screens before operating
the pump, as failure to do so may cause the pump to fail,
voiding the warranty.
Impeller/Rotor Cleaning
• Remove the four screws to disconnect the water
chamber cover (Ex. 17).
aquascapeinc.com |
CAN (866) 766-3426 |
• Remove the impeller by pulling gently (Ex. 18).
Ex. 15
• Clean the impeller and internal pump body with Aquascape
Pump Cleaner Maintenance Solution (#91143), using a
sponge or soft-bristle brush (Ex. 19).
Ex. 16
• Re-install the impeller, making sure the gasket is in place
and the raised key on the impeller flange is aligned with the
matching notch in the face of the pump flange (Ex. 20).
US (866) 877-6637
Ex. 17
Ex. 18
Ex. 19
Ex. 20
7