製氷機 Diamond ICE25AのPDF 設置・使用・メンテナンスマニュアルをオンラインで閲覧またはダウンロードできます。Diamond ICE25A 15 ページ。 Automatic ice - cube maker production code: cb249a

Diamond ICE25A 設置・使用・メンテナンスマニュアル
electricity main.
The appliance is provided with an electronic device
for adjusting the quantity of ice dispensed each time.
To increase or decrease the dispensing time and
the proportionate quantity of ice dispensed, proceed
as follows:
remove the basin (26)
slacken off the screws (27) on the front panel
(28) using a crossheaded screwdriver
pull out the front panel (28) from above
turn the knob (29) on the electronic device
clockwise to increase the quantity of ice
dispensed whenever the button is pressed, and
anti-clockwise to reduce the quantity.
8.2

MODEL WITH COLD WATER DISPENSER

(Fig. 14)
The appliance is provided with a cold water
dispenser located beside the ice container.
To obtain cold water, place a glass under the outlet
and gently press the button (30) to turn on the water
tap.
Release the button to stop the flow of cold water.
If the appliance is already provided with a filter
located on the cold water supply circuit, read the
instructions on the filter label carefully and follow
the manufacturer's recommendations regarding the
replacement schedules.
9 MAINTENANCE
9.1 CLEANING THE SOLENOID VALVE FILTER
At least every two months, clean the filter (31
Fig. 15) located on the water inlet solenoid valve,
proceeding as follows:
Switch off the electric power supply by means
of the switch (9 Fig. 4), fitted during installation,
and disconnect the plug of the appliance from
its socket.
Shut off the water supply by turning the tap (10
Fig. 7) fitted during installation.
Unscrew the threaded ring nut (11a Fig. 15) of
the water feed hose, located at the outlet of the
solenoid valve at the rear of the appliance (front
for the built-in model). For the built-in model,
first remove the panel as indicated at point 5.2.a.
Using a pair of pliers, remove the filter (31 Fig.
15) from its seat without damaging the water
feed pipe connector.
Place the filter under a strong jet of water to
remove residue, but replace the filter if it is
excessively dirty.
After having carried out the cleaning operations, refit
the filter and hose pipe taking the necessary
precautions described earlier in the Instruction
Manual.
When the operations have terminated, turn on
both the electricity supply and water supply.
9.2 AIR-COOLED MODELS
For air-cooled models, it is very important to keep
the finned condenser clean.
Have the finned condenser cleaned at least once
every two months by an authorized Technical
Service Center, which can include this operation in
the scheduled maintenance program.
9.3
CLEANING AND SANITIZING THE ICE
TRAY (Fig. 16-17-18)
All cleaning operations must be carried
out only after the electric power and water
supplies have been disconnected, as described
previously.
Open the door (32) located on the front of the
appliance.
The inside basin of the model with continuous
delivery can be accessed from the front upper panel
(33). To access it, disconnect the power supply and
follow the procedure according to the indications in
Figure 16.
a. Remove the seal (34).
b. Fully unscrew the two screws (35).
c. Pull the lower part of the panel (34) until the tab
fits flush against the cell.
Lower the panel to free the upper pins. Extract the
panel from above.
Unscrew the two knobs (36) on the flap panel (37)
to detach the panel and access to the sprayer bank.
Clean the panel (37) and the flaps (20).
Remove the slide grille (38) as shown in Figure 17,
and clean it.
Remove the sprayer bank (39) from its seat, as
21