• Always operate the pump fully submerged. Failure to do
so will overheat the pump and cause it to fail, thus voiding
the warranty. DO NOT OPERATE DRY.
• Use only in fully assembled state, and be sure that both
the upper and lower cage screens are snapped together.
Failure to operate the pump without the filter cage closed
will allow large debris to enter the pump, causing the
pump to fail and voiding the warranty.
• DO NOT wear loose clothing that may become entangled
in the impeller or other moving parts.
• Keep clear of suction and discharge openings. DO NOT
insert fingers in pump with power connected.
• DO NOT pump hazardous materials or liquids, such as oil,
saltwater or organic solvents.
• DO NOT block or restrict discharge.
• Products returned must be cleaned, sanitized, or
decontaminated, as necessary prior to shipment so as
to ensure that employees will not be exposed to health
Model Number
Maximum Flow Rate (GPH)
Maximum Head Height
Motor Type
Wattage
Amperage
Power Cord Length
Pump Discharge Diameter
Multi-Hose Fitting Diameters

Installation

• The AquaForce Solids-Handling Pond Pump is designed
to be submerged directly into the pond. To maximize pond
circulation, locate the AquaForce pump as far away as
possible from the location of the water entering back into
the water feature (Ex. 1).
• It is recommended that the pump NOT be positioned in
the deepest area of the pond (Ex. 1). This will protect the
fish by preventing the pond from completely draining in the
case of leak in the plumbing or filter. Bricks or stones can
be used, if needed, to raise the pump up off the bottom of
the pond.
4
AquaForce Solids-Handling Pond Pump Specs
1000
1800
1,070
2,149
10'
16.5'
Asynchronous
Asynchronous
55
160
.51
1.33
25'
25'
1.5" MPT
1.5" MPT
1", 1.25", 1.5", 2"
1", 1.25", 1.5", 2"
Ex. 1
US (866) 877-6637 |
hazards in handling said material. All applicable laws and
regulations shall apply.
IMPORTANT: Aquascape, Inc. is not responsible
for losses, injury, or death resulting from a failure
to observe these safety precautions, misuse or
abuse of pumps or equipment.
AquaForce
Solids-Handling Pond Pump
®
Specifications
• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
• Thermally protected
• This pump has been evaluated for use with water only
• Input amps & wattage: see chart below
2700
2,695
14'
Asynchronous
147
1.25
25'
1.5" MPT
1", 1.25", 1.5", 2"
1", 1.25", 1.5", 2"
• The AquaForce includes a wide assortment of fittings to
choose from. Select the appropriate fitting(s) needed for
your application.
• The threaded collar, on all of the fittings, enables the
AquaForce pump to be installed and removed without the
need for any tools (Ex. 2). Do not use tools to attach the
fittings onto the pump discharge (Ex. 3). Fittings need to
be hand-tightened only.