- ページ 15

ビデオカメラ Panasonic WVNP244 - COLOR CCTV CAMERAのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Panasonic WVNP244 - COLOR CCTV CAMERA 24 ページ。 Ip video cameras
Panasonic WVNP244 - COLOR CCTV CAMERA にも: 仕様 (2 ページ), パンフレット (2 ページ), 参考 (2 ページ), 参考 (2 ページ), 取扱説明書 (24 ページ), マニュアル (2 ページ), 取扱説明書 (24 ページ), 統合ノート (8 ページ)

Panasonic WVNP244 - COLOR CCTV CAMERA 取扱説明書
Important:
• Use all of 4 pairs (8 pins) of the LAN
cable.
• The maximum cable length is 100 m.
• Make sure that the PoE device in use is
compliant with IEEE802.3af standard.
• When connecting both the AC 24 V/DC
12 V power supply and the PoE device
for power supply, PoE will be used for
power supply.
• When disconnecting the LAN cable
once, connect the cable again after 2
seconds or more from the disconnection.
When the cable is connected before 2
seconds passed, the power may not be
supplied from the PoE device.
• Refer to the provided slip (Recommend-
ed network devices for PoE (IEEE802.3af
compliant) connection with the WV-
NP244) for applicable PoE devices.
Step 4
Connect a LAN cable (category 5 or better)
to the network connector on the rear of the
camera.
10BASE-T/
MONITOR OUT
LINK
100BASE-TX
ACT
INITIAL SET
SD
EXT I/O
CARD
1 2 3 4
POWER
GND
AC 24V IN : 1L – 2N
DC 12V IN : ! – @
Step 5
Connect an external device to the EXT I/O
connector.
When connecting an external device, remove
9 mm – 10 mm of the outer jacket of the
cable and twist the cable core to prevent the
short circuit first.
LAN cable
ALARM OUT
(Alarm out terminal)
ALARM IN
(Alarm in terminal)
AUX OUT
(AUX out terminal)
GND
Specification of cable (wire):
AWG #22 - #28
Single core, twisted
Important:
• Do not connect 2 wires or more directly
to a terminal. When it is necessary to
connect 2 wires or more, use a splitter.
<Ratings>
• ALARM IN
OFF: Open
ON: Make contact with GND (0.5 mA or
more)
• ALARM OUT
OPEN: Open Collector or DC 4 V –
DC 5 V
Maximum applied voltage: 20 V
CLOSE: Make contact with GND
(100 mA or less)
• AUX OUT
OPEN: Open Collector or DC 4 V –
DC 5 V
Maximum applied voltage: 20 V
CLOSE: Make contact with GND
(100 mA or less)
Important:
Connect an external device with verifying
that the ratings are within the specifica-
tions above.
Cut
Approx.
9 mm - 10 mm
15