USAGE INSTRUCTION

Fix the adapter firmly to drum can's larger ajutage (outlet, G2). [Drawing 1]
Release the Push Screw and insert the pipe into the adapter until you can't
insert it any further. [Drawing 1]
Manually tighten the Push Screw. [Drawing 1]
Insert into the smaller ajutage (outlet, G3/4): the regulator (for delivery) or
the ejector (for suction). Fix it firmly. [Drawings 2 & 3]
Close the air valve by setting it perpendicularly to the hi-coupler 20PM.
[Drawings 2 & 3]
Close the suction/delivery valves [A] & [B] by setting them perpendicularly to
the hose. [Drawings 1 & 4]
[Delivery only] Close the adapter's P-cock. [Drawing 1]
Connect the compressor to hi-coupler 20PM. [Drawings 2 & 3]
Open the air valve – the compressed air enters the can (below 1 MPa).
[Delivery only] Make sure the pressure (measured by the meter) is stabilized
at 0.05 MPa (0.5 kgf/cm
). [Drawing 2]
2
Opening suction/delivery valves [A] & [B] begins suction/delivery.
[Delivery]
When the liquid in drum can runs out, the air will come out of a delivery line.
[Suction]
When the liquid fills the can full, the float ball will block the suction line.
The suction will automatically stop. [Drawings 1 & 4]
Closing the suction/delivery valve [B] stops suction/delivery. [Drawing 4]
After use, close the air valve and suction/delivery valve [A]. Open the
suction/delivery valve [B] to let out the leftover liquid from the hose. After
that, close the suction/delivery valve [B]. [Drawings 1 & 4]
[Delivery only] Open the adapter's P-cock to restore normal pressure in the
drum can.
Leftover pressure may be very dangerous. It may splash the liquid and
push the pump out of the can. Make sure the pressure meter shows "0".
Please use a ground wire for protection against fire and explosion.