- ページ 14

デジタルカメラ Panasonic AG-HPX250EJのPDF 電気調整をオンラインで閲覧またはダウンロードできます。Panasonic AG-HPX250EJ 20 ページ。 Memory card camera recorder
Panasonic AG-HPX250EJ にも: 取扱説明書 (36 ページ)

Panasonic AG-HPX250EJ 電気調整

2-1-4. White Balance Adjustment

1. Set the each switch of camera recorder as follows.
● GAIN switch: L (0dB)
● AUTO/MANUAL switch: MANUAL
● WHITE BAL switch: B
● USER switch: OFF
● SHUTTER: OFF
2. Open the OPTION MENU screen and confirm that the item "P.A.P FILTER" is set as "TYPE2" (MAIN MENU >
OPTION MENU > P.A.P FILTER).
NOTE: Push the "DISP/MODE CHK" and "MENU" button simultaneously, and then OPTION menu can be
displayed in addition to a setup menus (12. OPTION MENU).
3. Open the SYSTEM SETUP screen and set the item "SYSTEM MODE" to "1080/59.94i" (MAIN MENU >
SYSTEM SETUP > SYSTEM MODE).
4. Connect the WFM to the SDI OUT with 75ohm termination.
5. Connect the VIDEOI OUT to Monitor TV.
6. Aim the Camera-Recorder at white chart under the Halogen lamp condition (3100K, 2000Lux).
7. Select "CAM(C)" section after start up the PC EVR software, and click "OK" button.
8. Select "Adjustment Tool" in "Tools(W)" menu, Adjustment Tool screen will appear on screen.
9. Click the "Start" button for P.A.P Type2 (AWB is executed automatically.).
10. Adjust IRIS so that the white level is 70 to 90% with IRIS ring.
11. Clicking the "Execute" button for P.A.P Type2, the white balance adjustment is executed automatically.
12. When the adjustment is completed, the message "White Balance Completed!" is displayed in the STATUS
column on the Adjustment Tool screen.
13. Confirm that the vector dot is located at the zero point in the WFM (vector scope).
14. Confirm that there is no colored on Monitor TV.
15. Open the OPTION MENU screen and set the item "P.A.P FILTER" to "TYPE1" (MAIN MENU > OPTION
MENU > P.A.P FILTER).
NOTE: When a setting of P.A.P FILTER is changed, the message "TURN POWER OFF" appears on the LCD
screen. Then turn the power of camera recorder to off and turn it back on again.
16. Click the "Start" button for P.A.P Type1 (SHUTTER is set to 1/250 automatically.).
17. Adjust IRIS so that the white level is 70 to 90% with IRIS ring.
18. Clicking the "Execute" button for P.A.P Type1, the white balance adjustment is executed automatically.
19. When the adjustment is completed, the message "White Balance Completed!" is displayed in the STATUS
column on the Adjustment Tool screen.
20. Confirm that the vector dot is located at the zero point in the WFM (vector scope).
21. Confirm that there is no colored on Monitor TV.
ELE-13