- ページ 6

デジタルカメラ Panasonic AW-HEA10WEJのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Panasonic AW-HEA10WEJ 40 ページ。 Control assist cameras
Panasonic AW-HEA10WEJ にも: 取扱説明書 (34 ページ)

Panasonic AW-HEA10WEJ 据付・取扱説明書
Installation precautions (continued)
Before installation, always disconnect the power
„
„
plug.
When installing, always use the supplied components.
Do not disassemble or modify the wall mount adaptor.
Tightening up the mounting screws
„
„
• Tighten up the screws and bolts securely to the degree that is
appropriate for each of the materials used in the mounting location
and structures.
• After tightening up the screws and bolts, check that there is no
unsteadiness and that the parts have been tightened securely.
• Use the specified tools to firmly tighten the screws to the
specified tightening torques.
Screw
Tightening torque
diameter
M3
0.78 N · m {8 kgf · cm}
M4
1.47 N · m {15 kgf · cm}
• Tighten up the screws using the specified torque driver. Do not
use electrical drivers or impact drivers.
When the unit is no longer going to be used, do
„
„
not leave it lying around, but be absolutely sure
to dispose of it properly.
For details on how to remove the unit, refer to "How to remove the
camera" (→ page 17).
Do not attach a filter, hood, extender or other
„
„
parts to the unit.
Use the dedicated AC adaptor and power cable
„
„
provided with the unit.
Connect the AC adaptor and power cable to the power inlet
securely.
Installing the AC adaptor
„
„
• Do not place the AC adaptor directly onto the ceiling panel or
other such surface. Extreme danger is posed when water has
collected on the surface as a result of leaking rain, for instance.
Secure the adaptor firmly to the bottom or other surface of a
reinforcing member made of channel steel where dust and other
foreign matter will not accumulate.
(→page 12)
• Secure the adaptor firmly so that there will be no chance that it will
fall off or fall down. Secure it using a strength which can withstand
the mass (approx. 0.3 kg (0.66 lb)) of the AC adaptor.

Adjusting the shooting range

You can manually adjust the pan (approximately 45° left and right) and tilt (approximately 30° up and down) for the lens of the unit.
Adjust the shooting range depending on the installation location.
Left:
Approx. 45°
Up and down:
Approx. 30°
6
Angle of view:
Approx. 95°
Right:
Approx. 45°
Install the accessory AC adaptor near the main
„
„
power outlet, and position it in such a way
that its power plug can be plugged into and
unplugged from the outlet easily.
When connecting the AC adaptor to a power outlet on the ceiling or
on any other surface where dust may collect, wipe off the dust on
the power plug at periodic intervals as an anti-tracking measure.
Connecting the power cable
„
„
Be absolutely sure to connect the power cable of the AC adaptor
through a circuit breaker using one of the following methods.
(1) Connect the power cable through a power control unit.
(2) C onnect the power cable to a circuit breaker in a power
distribution panel with a contact distance of 3.0 mm (1/8
inches) or more.
Use a circuit breaker which is capable of shutting off all the
poles of the main power supply with the exception of the
protective ground conductor.
(3) I nstall the AC adaptor near the power outlet, and connect it
through the power plug.
If there is a possibility of noise interference
„
„
Wire the cables so that the power cable (ceiling light cord) of AC
100 V
(AC 220 V
) or more, and the signal cable are placed at
*
1
*
2
least 1 meter (3.3 ft) apart.
Alternatively, run each cable through its own metal conduit. (The
metal conduits must be grounded.)
For AW-HEA10WPJ, AW-HEA10KPJ
*
1
2
For AW-HEA10WEJ, AW-HEA10KEJ
*
Radio signal interference
„
„
If the unit is positioned near a TV or radio transmitting antenna or a
strong electrical field or magnetic field (such as that generated by a
motor, transformer or power lines), its images may be distorted and/
or the images may be affected by noise.
When connecting the cables, ensure that the
„
„
connector areas will not be subject to any load.
Doing so may cause malfunctioning.
PoE power supplies
„
„
Use a PoE (IEEE802.af) compatible hub or power supply device.
Angle of view: