- ページ 15

タンク設備 AQUATECH AquaBreak AB5のPDF インストラクションをオンラインで閲覧またはダウンロードできます。AQUATECH AquaBreak AB5 18 ページ。 Breaktank & pumpset for backflow protection to fluid category 5

 
2.3.4 
TROUBLE SHOOTING GUIDE
 
Symptoms 
No water, pump will not start 
No water, pump does run 
Reduced/intermittent flow 
Pump continues to run with all 
outlets closed or pump cycles on and 
off (hunts) 
 
If a problem persists, contact AQUATECH‐PRESSMAIN service department quoting the serial 
number WN: _______ (on control panel fascia) 
 
 
AquaTech-Pressmain Instruction Manual\AquaBreak
 
Possible Cause 
Electrical supply off 
Pump seized (motor buzzes) 
Pump seized (internal motor 
thermotrip operated) 
Dry run protection initiated (see 
2.3.3.3) 
Maximum system head exceeds 8m 
for AB5‐35 or 12m for AB5‐45. 
Pump stopped on low water (dry 
run), no water in break tank 
Pump air‐locked 
Pump partially air‐locked 
Mains water/Pump inlet strainer 
blocked/partially blocked 
Air in system 
Dry run protection initiated (see 
2.3.3.3) 
Leak in system 
Control vessel air‐charge incorrect 
Jammed flow switch 
Jammed non‐return valve 
Damaged flow or pressure switch 
 
AquaBreak Series  
Check 
Check power supply, electrical 
isolator, fuses, RCD, motor circuit 
breaker, wiring connections 
Pump has not been run regularly 
(weekly). Contact Aquatech 
Pressmain service 
Pump has not been run regularly 
(weekly). Contact Aquatech 
Pressmain service 
Breaktank is empty, check inlet 
valve/strainer and solenoid valve 
operation. Check mains water 
supply. Check pump suction 
strainer/inlet filter 
Pump start Pressure switch will not 
operate if maximum system head is 
exceeded. 
Tank Level Control relay fault, switch 
power off, wait 10 seconds and 
switch power on again to reset 
control relay. 
Vent/prime pump to remove all air. 
Check pump suction strainer/inlet 
filter 
Vent/prime pump to remove all air 
Clean mains water/pump inlet 
strainer (section 2.4) 
Purge air from all system pipework 
Breaktank is empty, check inlet 
valve/strainer and solenoid valve 
operation. Check mains water supply 
Check all system pipework and 
outlets for leak 
Check air charge pressure in vessel 
Remove discharge hose and check 
flow switch for free movement, no 
debris 
Remove non‐return valve and check 
for free movement, no debris 
Contact Aquatech Pressmain service 
Page 15 of 18