- ページ 31

スイッチ HP StorageWorks 2/16 - SAN SwitchのPDF リリースノートをオンラインで閲覧またはダウンロードできます。HP StorageWorks 2/16 - SAN Switch 32 ページ。 Fabric os commands
HP StorageWorks 2/16 - SAN Switch にも: 更新マニュアル (9 ページ), 取付説明書 (20 ページ), ユーザーマニュアル (22 ページ), ファームウェア・リリース・ノート (14 ページ), リリースノート (16 ページ), インストレーション・マニュアル (14 ページ), リリースノート (10 ページ), クイック・リファレンス・マニュアル (5 ページ)

HP StorageWorks 2/16 - SAN Switch リリースノート
Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-STATS (C3FRX), 1
Critical
DIAG-STATS (FRX), 1
Critical
DIAG-STATS (FTX), 1
Critical
DIAG-TBRAM_INC_
RWTEST, 1
Critical
DIAG-TBRAM_INC_
WTEST, 1
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes
Probable Cause
Port counter value did not match the
number of frames actually
transmitted. In this case, C3FRX =
number of Class 3 frames received.
This can be caused by a faulty cable
or deteriorated SFP. It can also
indicate deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest command,
if problems are found.
Port counter value did not match the
number of frames actually
transmitted. In this case, FRX =
number of frames received. This can
be caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest command,
if problems are found.
Port counter value did not match the
number of frames actually
transmitted. In this case, FTX =
number of frames transmitted. This
can be caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest command,
if problems are found.
ASIC internal registers failed
read-modify-write operation. This
usually indicates an ASIC failure.
This message is generated by the
turboramtest command, if
problems are found.
ASIC internal registers failed write
operation. This usually indicates an
ASIC failure. This message is
generated by the turboramtest
command, if problems are found.
Documentation Updates
Recommended Action
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
31