- ページ 31
スイッチ HP StorageWorks 8/40 - SAN SwitchのPDF リリースノートをオンラインで閲覧またはダウンロードできます。HP StorageWorks 8/40 - SAN Switch 43 ページ。 Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
HP StorageWorks 8/40 - SAN Switch にも: リリースノート (30 ページ), リリースノート (29 ページ), リリースノート (32 ページ)
![HP StorageWorks 8/40 - SAN Switch リリースノート](/uploads/products/server2/3836007/3836007.png)
When the switch name is set using CLI and then read using the Read
Port Address Name x'B2' command to the CUP Port x'FE' it returns the
switch name with a x'7F' attach after the last character in the Switch
Name.
A failed Pause frame (sent during firmwaredownload process in
Interop Modes 2 and 3), causes a fabric rebuild.
In some instances, HCL on an HP StorageWorks 8/40 SAN switch in
Interop Mode requires the use of the -o option.
A turboramtest failure does not fully disable the port on an HP
StorageWorks 8/80 SAN switch.
Web Tools: The HP StorageWorks DC04 SAN Director attention LEDs
on the switch view GUI window do not turn amber when blade needs
attention.
N-Port between AG and Edge Switch (300) may become stuck at E-
Port Unknown state.D
After multiple successive fastboots of an HP StorageWorks DC04 SAN
Director, there was a panic due to the zone daemon dying.
FICON PTP VTS Selective Resets and Aborted sequences caused by
incorrect entry into FICON tape read pipelining.
EX_Port fails to come online after downgrading firmware from Fabric
OS 6.x to 5.3 under certain conditions.
Tstimezone settings cannot be changed or restored with config-
download.
If a large number of EX_Ports are enabled at the same time, occasion-
ally some fail due to incompatible flow control parameters.
In some instances, portshow may display inaccurate port authentic-
ation description or state after a CP failover.
Internal server ports on embedded platform: traffic may stop due to
loss of buffer credit.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option to override the co-
operative HCL feature.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable and then enable the port on
the AG to bring the port back online
as an N-Port.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Fastboot a single time.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Remove the ts.tz parameter in the
config file and then download.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Portdisable and then enable the
EX_Ports that failed.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0b release notes
31