- ページ 5
浄水器 Aquatek ATUN2001のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Aquatek ATUN2001 10 ページ。 Upflow neutralizers
***NOTE***
Since both calcium carbonate and magnesium oxide increase hardness of your water,
if your dwelling contains a tankless water heater, it is recommended that a water softener be installed
after the ATUN Series Upflow Acid Neutralizer System to help prevent the heater coil from plugging with
hardness material.
About Your ATUN
How Does my Neutralizer Filter Work?
The low pH (acid) water passes through a special limestone neutralizing
media and slowly dissolves the media raising the pH to approximately 7
units (neutral) or higher. Periodic media replenishment is therefore re-
quired. The frequency and amount of media replenishment depends on
the volume of water used and how acidic the water is before treatment.
The lower the pH (acidity) of the water being treated, the greater the at-
trition rate of the media and the slower the water should pass through the
bed. The unit should be sized according to the level of pH and existing flow
rate. Your dealer can provide an estimate of your replenishment require-
ments.
ATUN Series Upflow Acid Neutralizers virtually eliminate the possibility of
media bed "cementing" because the water to be treated actually "up-
flows" through the neutralizer media bed! This procedure requires NO
electricity or backwashing.
A large fill-port permits easy replenishment of the "sacrificial" neutralizing
media by the homeowner or a service technician.
There are different media types available which can be used in this ATUN
Series Upflow Acid Neutralizer System. Each is designed to improve a par-
ticular aesthetic problem. None of them should be used to make non-po-
table water safe to drink. The following descriptions indicate not only what
the media is designed to do, but also points out their limitations.
Neutralizer Blend
Neutralizer media is typically a blend of calcium carbonate and mag-
nesium oxide. This media is used to elevate the pH of acid water and is
generally used when the pH is approximately 5.5 - 6.0 units. The neutral-
izer media dissolves when water with a low pH passes through. The blend
is used to take advantage of the fast, vigorous pH adjusting capabilities of
magnesium oxide and the slow, long-lasting capabilities of the calcium
carbonate. Neutralizer is typically not recommended when the pH of the
raw water is below 5.5 units, because the dissolve rate would be high and
thus constant maintenance of the ATUN Series Acid Neutralizer System
would be necessary. In these cases contact our Customer Service Depart-
ment at 1-877-414-7873 for recommendations.
***NOTE***
Since the neutralizer media dissolves as it elevates pH level, it will in-
crease the hardness of your water. If your dwelling contains a tankless water heat-
er, a water softener must be installed after the ATUN Series Upflow Acid Neutralizer
System to help prevent the heater coil from plugging with hardness material.
Calcium Carbonate
Calcium carbonate can be used when only a slight pH adjustment is
required (typically 6.0 to 6.8 units). Calcium carbonate is sacrificial (dis-
solves) when adjusting pH and will thus increase hardness as well. Re-
plenishment will be required periodically, once again depending on raw
water pH and water consumption.
UNITED WATER INC.
A
AtuN-S
quAtek
erieS
u
G
Ser
uide
5