- ページ 48
スイッチ HP StorageWorks Fabric OS 4.4.0fのPDF リリースノートをオンラインで閲覧またはダウンロードできます。HP StorageWorks Fabric OS 4.4.0f 48 ページ。 Hp storageworks fabric os 4.4.0f release notes (aa-rw89a-te, october 2005)
Table 10
Fabric OS 4.4.0f closed issues summary
Closed defect
Issue: MSd panic while processing a
bad frame sent by a remote switch
that is out of memory.
Symptom: FOS 4.4.x switch panics
in msd when the remote switch has
an out-of-memory or low-memory
signature. The problem only
happens if the remote switch is
running a version of code older than
FOS 4.4 and is also low on or out of
memory.
Issue: Switch panic on FOS4.4.x with
zoned assert on invalid interface
identifier.
Symptom: Zone panic with assert at
merge/zn_merge_dbg.c:453, with
call from
zoneDomain_portsIfId.
Issue: SAN Director 4/256 panic
(zoned ASSERT when
trans_in_progress is detected) when
multiple changes take place without
Reliable Commit Service (RCS).
Symptom: Zone daemon causes
switch panic.
48
Closed issues from Fabric OS 4.4.0f
Status
Fixed.
Workaround: Disable F ports
before upgrade.
Workaround: Enable RCS, avoid
multiple transactions initiated in
parallel.